The modern Furnace Sequence of carrying out - Trying To Diagnose A question With Your Furnace?

Before we begin, we must say only mighty persons should attempt working on a gas furnace. Please consult a pro assistance business for repairs or for definite diagnosing!

Remember when furnaces were pretty simple? There was a pilot and a thermocouple, a incorporate of safety controls, a blower assembly, a set of burners and of policy the heat exchanger. The down side of these old furnaces was the cost to control them as they were ordinarily about 50% efficient. The modern furnaces of today run in the middle of 80% and 95% efficient.

Honeywell Pressure Switch

We will talk about the typical 80% particular stage heating gas furnace in this narrative as this is the most base out there these days.

On a signal from the room thermostat that heating is needed, the first thing that takes place is the draft inducer begins running and creating a draft in the heat exchanger. If there is no obstruction in the flue pipe of the furnace, the inducer will send a small pressure to the pressure switch via a small rubber tube, obviously, this tubing must be free of debris or any cracks. If there is adequate draft, this will close contacts inside the pressure switch. The pressure switch then sends a signal down to the control board which is ordinarily mounted in the blower section. There are varied safety controls such as, but not wee to, over climatic characteristic limit switches, plenum thermostats, flame sensors, and roll out switches that must be closed, but if they are and the control board is good, a signal will be sent to the ignition device. There are many ignition systems used together with intermittent spark ignition, direct spark ignition, hot face ignition, electronic ignition, standing pilots and others. Most furnaces at this time use hot face ignition with a flame sensor. So we will incorporate this narrative on the hot face ignition ideas that uses a flame sensor.

There are several dissimilar types of hot face ignitors on the market. The most base is the Silicone Carbide type which is Very brittle and breaks easily. Do not cope this type by the carbide section as the oil from your hands will shorten the life span. This type has a life expectancy of 3-5 years usually. There are flat ones and round spiral versions of these.

The next type is the Silicone Nitride which will last much longer and do not break easily, some of them are meant for 24 volt systems as in the Honeywell Smart Valve systems, and Trane 80 volt systems.

There are also older systems that use a hot face ignitor that doesn't use a separate flame sensor but rather once they glow orange then switch over to sense the flame. These systems are called radiant systems and have been proven unreliable and sometimes unsafe as they are not sensing a flame on all burners, only the one the ignitor is mounted on. Most furnace manufacturers are requiring you to add a flame sensor when you change a control board.

Assuming the control board "sees" all the safety controls are closed and it has a signal from the pressure switch, it will then send 120 volts to the hot face ignitor which is ordinarily mounted on the right side of the burners. (Be aware that some ignition systems use 24 volts for lighting a pilot and Trane and some others use a 80 volt Silicone Nitride ideas on Some of their models). Once the hot face ignitor glows orange you should hear a click which is the gas valve chance to let gas flow to the burners. This should give almost instant ignition on all burners. The flame sensor is a small white ceramic electrode mounted on the left side of the burners. It's job is to "sense" a flame on the burner which is at the opposite side of the furnace from the hot face ignitor. If it doesn't get a flame within about 10-15 seconds, it will shut the burners back off for safety. ordinarily if a furnace goes through (3) cycles like this, it will go into lock out. To get it out of lock out you will need to shut the power to the furnace off and back on. Flame sensors should be cleaned with sandpaper once a year as part of maintenance.

Once all the burners are lit and running, the control board will send a signal to the blower motor to start.

Be advised however, there are Many control boards together with intergrated control boards where all functions of the furnace are controlled by this board, also out there are ignition modules used for ignition only and a separate fan timer control board that only starts and stops the blower motor as well as monitoring safety controls.

Before you even Think about working on your furnace, please remember this is a inherent lethal piece of tool which takes a great deal of training for a assistance person to work on. Folks may want to save money by doing their own work, but there is much to be said about a allowable diagnoses by a reputable business let alone any dangers to physical harm from inexperienced habitancy working on this equipment. If in doubt "Don"T Do It"